Vue de la page 0
UNOsphere
rapid S
Cation Exchange Media
Instruction Manual
Catalog #s
156-0211
156-0213
156-0215
156-0217
Please read these instructions prior to using UNOsphere
ion exchange media. If you have any questions or comments
regarding these instructions, please contact your Bio-Rad
Laboratories representative.
................................................................................................................................
10010339A.qxp 3/3/2008 7:50 AM Page COV3
Vue de la page 0
1 2 3 4 5 6 7 8 9 10

Résumé du contenu

Page 1 - Instruction Manual

UNOsphere™rapid SCation Exchange Media Instruction ManualCatalog #s156-0211156-0213156-0215156-0217Please read these instructions prior to using UNOsp

Page 2 - Table of Contents

10010339 Rev ALife ScienceGroup00-0000 0000 Sig 1207Bulletin 0000 US/EG Rev ABio-Rad Laboratories, Inc.Web site www.bio-rad.com USA 800 4

Page 3 - Introduction

Table of ContentsSection 1 Introduction ...1Section 2 Technical Description ...

Page 4 - Column Packing

1Section 1IntroductionUNOsphere rapid S ion exchange media is a hydrophilic spherical polymeric beaddesigned for the separation of proteins, nucleic a

Page 5 - Column Packing Evaluation

2Section 3PreparationUNOsphere rapid S media is supplied fully hydrated in 20% ethanol as a 50% (v/v)slurry. For column packing, removal of the shippi

Page 6

3Packing Large ColumnsIn large columns, UNOsphere rapid S should be packed using a 20–50% slurry,ideally using a combination of axial and flow compres

Page 7 - Operation and Maintenance

4Fig. 1. A simulated chromatography profile from which HETP and Asvalues arecalculated. a b 10% of peak hihWh, width at half heigBed height = 20

Page 8

5Section 6Operation and MaintenanceUNOsphere media were designed to achieve the highest productivity (grams ofdrug per operational hour per liter of m

Page 9 - Ordering Information

6Table 2. Common Buffers for Cation Exchange Chromatography. Buffer Buffering RangeAcetic acid 4.8–5.2Citric acid 4.2–5.2HEPES 6.8–8.2Lactic acid 3.6

Page 10 - Laboratories, Inc

7 Section 10Regulatory SupportRegulatory support files are available for UNOsphere rapid S media. If you needassistance validating the use of UNOspher