Foresight
RoboColumn Units
200 and 600 µl
Instruction Manual
Catalog Numbers
732-4801 732-4816
732-4802 732-4817
732-4804 732-4819
732-4805 732-4820
732-4807 732-4822
732-4808 732-4823
732-4813 732-4825
732-4814 732-4826
Vue de la page 0
1 2 3 4 5 6 ... 23 24

Résumé du contenu

Page 1 - 200 and 600 µl

Foresight™ RoboColumn Units 200 and 600 µlInstruction ManualCatalog Numbers732-4801 732-4816732-4802 732-4817732-4804 732-4819732-4805 732-4820732-480

Page 2

6 Technical Support: 1-800-424-6723 • www.bio-rad.comTable 3. Recommended equipment for automated handling of Foresight RoboColumn units, continued.

Page 3 - Table of Contents

Technical Support: 1-800-424-6723 • www.bio-rad.com 7When using the HT process development approach for Foresight RoboColumn units, DoE is recomme

Page 4

8 Technical Support: 1-800-424-6723 • www.bio-rad.comSection 4ProtocolThe protocol is designed as a general guideline for working with Foresight™ Ro

Page 5 - Introduction

Technical Support: 1-800-424-6723 • www.bio-rad.com 92. Remove excess storage solution from needle adaptor inletRemove remaining storage solution

Page 6 - Characteristics

10 Technical Support: 1-800-424-6723 • www.bio-rad.com5. Experiment setup with the Te-Chrom Wizarda. Hardware configuration• Select the appropriat

Page 7

Technical Support: 1-800-424-6723 • www.bio-rad.com 11d. Configure your process steps• Defiine a process step name such as Equilibration• Check t

Page 8 - Advice on Handling

12 Technical Support: 1-800-424-6723 • www.bio-rad.com • Check the waste option if appropriate:i. When checked, the waste tray will be engaged by

Page 9

Technical Support: 1-800-424-6723 • www.bio-rad.com 13After the experiment setup the Te-Chrom Wizard will generate a chromatographic method in Fre

Page 10

14 Technical Support: 1-800-424-6723 • www.bio-rad.com8. Data plottingPlot the UV data against the fraction volume to create a pseudo-chromatogramN

Page 11

Technical Support: 1-800-424-6723 • www.bio-rad.com 15Section 5Troubleshooting GuideFault Possible cause ActionForesight™ RoboColumn units are clo

Page 12 - Protocol

Bio-Rad Technical Support For help and technical advice, please contact the Bio-Rad Technical Support department. In the United States, the Technical

Page 13

16 Technical Support: 1-800-424-6723 • www.bio-rad.comSection 6Ordering InformationForesight RoboColumn units 200 and 600 µlProduct Mode Catalog #Fo

Page 14

Technical Support: 1-800-424-6723 • www.bio-rad.com 17Foresight™ Chromatography Media Filter PlatesProduct Mode Catalog #Foresight™ Nuvia™ S Filte

Page 15

18 Technical Support: 1-800-424-6723 • www.bio-rad.comForesight™ Chromatography Media ColumnsProduct Mode Catalog #Foresight™ Nuvia™ S Column, 1 mlS

Page 17

Life Science Group Sig 121110027565 Rev A US/EGBio-Rad Laboratories, Inc. Web site www.bio-rad.com USA 800 424 6723 Australia 61 2 9914 280

Page 18

Table of ContentsBio-Rad Technical Support iiLegal Notices

Page 20 - Ordering Information

Technical Support: 1-800-424-6723 • www.bio-rad.com 1Section 1IntroductionForesight™ RoboColumn units are prepacked chromatography microcolumns us

Page 21

2 Technical Support: 1-800-424-6723 • www.bio-rad.comSection 2CharacteristicsForesight™ RoboColumn units are ready-to-use chromatography microcolumn

Page 22 - Chromatography Media Columns

Technical Support: 1-800-424-6723 • www.bio-rad.com 3Table 2. List of Bio-Rad chromatography media.Chromatography MediaModeInstruction Manual Lite

Page 23

4 Technical Support: 1-800-424-6723 • www.bio-rad.comSection 3Advice on Handling3.1 EquipmentForesight™ RoboColumn units are designed for robotic h

Page 24 - Laboratories, Inc

Technical Support: 1-800-424-6723 • www.bio-rad.com 5Table 3. Recommended equipment for automated handling of Foresight RoboColumn units, continue